...4 CONFIGURATION

4.5.5 Configuring the Digital Indicator View

Short Channel Tag
Current Value
Units
Alarm Status
76
Channel Units
Totalizer Units – see
Totalizer Value – see
Set to 'On' to enable the operator to display the Digital
Indicator view.
Set to 'On' to add the channel totalizer value and units to the
indicator displays (if the totalizer for that channel is enabled –
see Section 4.6.5).
Select the menu items to be accessible from the Digital
Indicator view.
Message select enable
Enables the Operator to activate one of 24 pre-configured
messages or a user-defined message.
Alarm acknowledge enable
Enables the Operator to acknowledge any alarms
associated with the current group.
Totalizer reset enable
Enables the Operator to reset the totalizer value to the preset
totalizer value on any or all channels.
Totalizer stop/go enable
Enables the Operator to start and stop the totalizer.
Channel select enable
Enables the Operator to display or hide individual channels.
Note. Menu items that are not enabled are greyed-out in the
Digital Indicator View menu.
below
Note
below
Note
N
ote. Displayed only if
the totalizer is enabled
for that channel (see
Section 4.6.5)