Got Side Settings - Mitsubishi Electric GOT2000 Series Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

7.3.2

GOT Side Settings

Setting communication interface
(Communication settings)
Set the channel of the connected equipment.
2.
1.
Select [Common]
[Controller Setting] from the
menu.
2.
The Controller Setting window is displayed. Select the
channel to be used from the list menu.
3.
Set the following items.
• Manufacturer: YOKOGAWA
• Controller Type: STARDOM/FA500/FA-M3
• I/F: Interface to be used
• Driver: Ethernet (YOKOGAWA), Gateway
4.
The detailed setting is displayed after Manufacturer,
Controller Type, I/F, and Driver are set.
Make the settings according to the usage
environment.
7.3.2 ■ Communication detail settings
Click the [OK] button when settings are completed.
POINT
POINT
POINT
The settings of connecting equipment can be
confirmed in [I/F Communication Setting].
For details, refer to the following.
1.1.2 I/F communication setting
3.
4.
GOT Net No.
GOT Station
GOT Ethernet
Setting
GOT
Communication
Click!
Port No.
Retry
Startup Time
Timeout Time
Delay Time
POINT
POINT
POINT
7. CONNECTION TO YOKOGAWA PLC
Communication detail settings
Make the settings according to the usage environment.
Item
Description
Set the network No. of the GOT.
(Default: 1)
Set the station No. of the GOT.
*1
(Default: 1)
Set the GOT IP address, subnet
mask, default gateway, peripheral S/
W communication port No.,
transparent port No.
Set the GOT port No. for the
connection with the Ethernet
module.
(Default: 5017)
Set the number of retries to be
performed when a communication
timeout occurs.
When receiving no response after
retries, the communication times
out.
(Default: 3times)
Specify the time period from the
GOT startup until GOT starts the
communication with the PLC CPU.
(Default: 3sec)
Set the time period for a
communication to time out.
(Default: 3sec)
Set the delay time for reducing the
load of the network/destination PLC.
(Default: 0ms)
*1
Each of [GOT Station] set in the communication detail setting
and [Station] set in the Ethernet setting must be set to
different station numbers.
Ethernet setting
(1) Communication interface setting by the Utility
The communication interface setting can be
changed on the Utility's [Communication setting]
after writing [Communication Settings] of project
data.
For details on the Utility, refer to the following
manual.
GOT2000 Series User's Manual (Utility)
(2) Precedence in communication settings
When settings are made by GT Designer3 or the
Utility, the latest setting is effective.
7.3 Ethernet Connection
Range
1 to 239
1 to 64
GOT
Ethernet setting
7
1024 to 5010,
5014 to 65534
(Except for 5011,
5012, 5013 and
49153)
0 to 5times
3 to 255sec
1 to 90sec
0 to 10000
(
10 ms)
7 - 17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents