7.4.1
YOKOGAWA FA500/FA-M3
Series
Device name
Setting range
*1
X00201 to X71664
Input relay (X)
Output relay (Y)
Y00201 to Y71664
Internal relay (I)
I1 to I65536
Link relay (L)
L1 to L71024
Common relay (E)
E1 to E4096
*3
M1 to M9984
Special relay (M)
*2
TU1 to TU3072
Timer (TU)
*2
CU1 to CU3072
Counter (CU)
Specified bit of the following
word devices
Word device bit
(Except Timer (TP, TS),
Counter (CP, CS))
Timer (TP)
TP1 to TP3072
*1
TS1 to TS3072
Timer (TS)
Counter (CP)
CP1 to CP3072
*1
CS1 to CS3072
Counter (CS)
File register (B)
B1 to B262144
Data register (D)
D1 to D8192
Common register (R)
R1 to R4096
Index register (V)
V1 to V256
Link register (W)
W1 to W71024
*3
Special register (Z)
Converting bit devices into
Bit device word
(Except Timer (TU), Counter
*1
Writing is not possible.
*2
Writing to continuous devices is not possible.
*3
The GOT cannot read or write data from/to consecutive
devices.
Device No.
representa
tion
Decimal
Decimal
Z1 to Z512
word
(CU))
7.4.2
YOKOGAWA STARDOM/FA-
M3 Series
Device name
*1
X00201 to X71664
Input relay (X)
Output relay (Y)
Y00201 to Y71664
*4
Internal relay (I)
L00001 to L08192
L10001 to L18192
L20001 to L28192
L30001 to L38192
Link relay (L)
L40001 to L48192
L50001 to L58192
L60001 to L68192
L70001 to L78192
Common relay (E)
*3
Special relay (M)
*2
Timer (TU)
*2
Counter (CU)
The bit specification of
the word device
Setting range of each word
(except Timer,
Counter)
Timer (TP)
*1
Timer (TS)
Counter (CP)
*1
Counter (CS)
*5
Filer register (B)
Data register (D)
Common register (R)
Index register
W00001 to W08192
W10001 to W18192
W20001 to W28192
W30001 to W38192
Link register (W)
W40001 to W48192
W50001 to W58192
W60001 to W68192
W70001 to W78192
*3
Special register (Z)
The word specification
of the bit device
Setting range of each bit
(except Timer,
Counter)
*1
Writing is not possible.
*2
Writing to continuous devices is not possible.
*3
The GOT cannot read or write data from/to consecutive
devices.
*4
With STARDOM, FA-M3 (F3SP59 only), if communications
that include the maximum device number (32767 or 65535)
occurs, system alarm "322 Dedicated device is out of range.
Confirm device range." may be detected.
If such system alarm is detected, do not use the last 15 bits.
*5
With STARDOM, do not use B32768 or later. Otherwise,
normal monitoring is not performed.
7. CONNECTION TO YOKOGAWA PLC
7.4 Device Range that Can Be Set
Device No.
Setting range
representa
tion
I1 to I65535
Decimal
E1 to E4096
M1 to M9984
TU1 to TU3072
CU1 to CU3072
device
TP1 to TP3072
TS1 to TS3072
CP1 to CP3072
CS1 to CS3072
B1 to B262144
D1 to D65535
R1 to R4096
V1 to V256
Decimal
Z1 to Z1024
devices
7 - 23