Safety Precautions
CAUTION
Instructions for rack installation
CAUTION
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Do
Note the following points when cleaning the power synchronized unit. Failure
to do so may cause device failure.
-
Make sure the power synchronized unit is turned off.
-
Do not allow liquids such as cleaner to get into the power synchronized
unit.
-
Never use organic solvents such as alcohol or thinner to clean the power
synchronized unit.
Do
Especially for an enclosed rack with doors, or when multiple devices are to be
mounted and running, it is important to realize that the temperature inside
the cabinet will be considerably higher than that of the room. Make sure the
rack internal ambient temperatures do not exceed the environmental
conditions for temperature described in
to do so may damage the power synchronized unit.
When installing the power synchronized unit with other devices into the same
rack, the airflow of the device installed on and under the power synchronized
unit may interfere with each other and reduce the effect of device cooling.
Make sure to leave plenty of room between the devices if required. Failure to
do so may damage the power synchronized unit and lead to malfunction.
When installing the power synchronized unit in a rack, be careful not to pinch
your fingers in the rack. Doing so may cause injury.
Install the blank panels provided with the rack where no other devices are
installed. Failure to do so may cause the power synchronized unit to overheat,
resulting in damage to the device.
When moving the rack after installing the power synchronized unit, make sure
to contact your sales representative or your maintenance engineer. Do not
move the rack by yourself. Doing so may cause injury and/or damage the
power synchronized unit.
14
Copyright 2017 FUJITSU LIMITED
"1.3 Specifications" (page
23). Failure
P3AM-8012-10ENZ0