Chapter 2 Installation

2.2 Preparation

2.2
Preparation
2.2.1

Installation Area

Placement area
Refer to the placement area of the rack to install the power synchronized unit and the AC sensor unit.
Installation condition
Install the power synchronized unit and the AC sensor unit in an area that meets all the conditions described
in
"Instructions for installation" (page 10)
2.2.2

Checking Power Sockets and Server UPS Unit Outlets

Check the required number and specifications of power sockets and server UPS unit outlets.
One power socket is required for each power synchronized unit. Make sure to check the plug type of the
power socket.
Connect the power synchronized unit to the same power socket line as the ETERNUS DX/AF.
Make sure each server UPS unit has an unused outlet for connecting a power synchronized unit or an AC
sensor unit. In addition, make sure to check the plug type of the outlet.
2.2.3

Preparing Power Cords

Note that power cords (for AC power input) for power synchronized units and power cords (for AC sensor) to
connect server UPS units to power synchronized units or AC sensor units are not supplied with power
synchronized units.
The IEC 60320-C14 port type is used for the AC IN ports and the SENSOR ports of the power synchronized units.
This port type is also used for the AC IN ports of the AC sensor units.
Check the specifications of the power sockets and server UPS unit outlets that are to be used for the power
synchronized units and AC sensor units. Prepare the required number of appropriate power cords.
Power cord (for AC power input)
-
Each power synchronized unit requires one power cord.
-
The voltage for the AC IN port is 10A 250V or less.
Power cord (for AC sensor)
-
Each server UPS unit that is to be connected to the power synchronized unit requires one power cord.
-
Each AC sensor unit requires one power cord.
Be sure that the power cords have the approval of the appropriate safety agencies of the country where the
equipment will be used.
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
of
"Safety
Precautions".
34
Copyright 2017 FUJITSU LIMITED
P3AM-8012-10ENZ0