Chapter 2 Installation
2.3 Installing in a Rack
■
Procedure for installing an AC sensor unit
Procedure
1
Open the front and rear doors of the rack.
2
Attach the M6 cage nuts to the rear rack pillar.
•
Attachment positions
Insert four M6 cage nuts in the 1st and 3rd holes above the AC sensor unit base line.
•
Attachment procedure
Clip the M6 cage nut tabs into the desired hole from the inside.
3
Attach the L-shaped brackets to the AC sensor unit.
Use four M3 cross recessed head screws with captive washer to attach the L-shaped brackets to the AC
sensor unit on both sides.
M3 cross recessed head
screws with captive washer
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
(Rear rack pillars)
3rd position
1st position
Base line of AC sensor unit
Top view
M6 cage nut
Rack pillar (square)
L-shaped bracket
L-shaped bracket
Copyright 2017 FUJITSU LIMITED
1U (AC sensor unit size)
M3 cross recessed head screws
with captive washer