...4 CONFIGURATION

4.5.4 Configuring the Process View

Note. The Process view is displayed only if the Totalizer option is fitted.
Alarms View – Totalizer Enabled
Totalizer Tag Name
Totalizer Value
Statistics View – Totalizer Enabled
Alarms View or Statistics View – Totalizer not Enabled
Alarms View – Alarms A and B not Enabled
Process
Recording
Chart
Bar
On
Process view enable
Statistics
Totalizer view select
1 2 3 X X
Menu enables
Process view enables
1. Message select enable
2. Alarm acknowledge enable
3. Totalizer reset enable
4. Totalizer stop/go enable
5. View select enable
54
Total Daily In Flow
Low In Flow Rate
0005402801
High In Flow Rate
litres
Alarm
Tag
Total Daily In Flow
Storage Tank 1 In Flow
0005402801
225.4
litres
Max
Values since last Totalizer Reset or Totalizer wrap.
Updated only if the Totalizer is Enabled and Running.
Low In Flow Rate
High In Flow Rate
Total Daily In Flow
Storage Tank 1 In Flow
0005402801
litres
Digital
Archive
In Flow
40
204.9
280
l/hr
Alarm Trip
Level
In Flow
204.9
110.9
201.0
l/hr
Min
Average
In Flow
40
204.9
280
l/hr
In Flow
204.9
l/hr
Set to 'On' to enable the operator to display the Process
view.
Select the Totalizer view to be displayed – Alarms or
Statistics. This setting can be changed by the operator if
'View select enable' is ticked below.
Select the menu items to be accessible from the Process
view.
Message select enable
Enables the Operator to activate one of 24 pre-configured
messages or a user-defined message.
Alarm acknowledge enable
Enables the Operator to acknowledge any alarms
associated with the current group.
Totalizer reset enable
Enables the Operator to reset the totalizers on any or all
channels.
Totalizer stop/go enable
Enables the Operator to stop and start totalizers on any or all
channels.
View select enable
Enables the Operator to select the Alarms and Statistics
views.
Note. Menu items that are not enabled are greyed-out in the
Process view menu.
Alarm Acknowledged
Channel Long Tag Name