3.
Start the debugging process. The available commands are as follows:
exit
exception
flash_erase
flash_program
help
mem
version
wrblock
wrmem
Note: The following paragraphs provide detailed descriptions of these commands.
4.
When done, type exit and press Enter.
6.3.1

Available Commands and Description

mem – Show Memory
This command determines whether a RAM address has a hardware problem or determines
if a particular FLASH ROM sector is empty. Use this command only under the direction of a
Siemens Rail Automation employee.
The MEM command takes either one or two arguments.
mem
[starting
decimal]
The contents of memory at the starting address are shown. If the user does not request the
optional number of bytes, the first 128 bytes of memory are shown. Otherwise the
requested number of bytes are shown.
version – Show version
The version of the WAG Boot Monitor appears with the date and time that the boot code
was compiled.
help – Lists available commands
Shows a list of the available debugging commands.
Document No.: COM-00-05-16
Version: C.1
Exits debugger
Displays CPU diagnostic information
Erases flash ROM
Programs flash ROM
Lists available commands
Shows memory
Shows version
Writes memory block
Writes memory
address
in
HEX]
6-3