Figure 2-53. Change ATCS Retry Timeout Scree

2.
To keep the current timer setting, press ENTER. To change the timer setting, enter the new
value and then press ENTER. Entry can be any value from 20 to 65535.
The user will be returned to the Second Configuration Menu.
3.
Prior to exiting the First Configuration Menu, select "Save changes then restart" to save
changes and restart the WAG.
2.6.24

ATCS Max Retries

ATCS Max Retries is used when the serial interface is configured for Genisys ATCS Office. It
designates the number of times to retry the sending of an ATCS message before giving up after
waiting for an acknowledgement.
The default value is 3.
To set the ATCS Max Retries value:
1.
On the Second Configuration Menu, select "ATCS Max retries" count to be set. The Change
Genisys ATCS Maximum Retry Count screen appears.

Figure 2-54. Change ATCS Retry Timeout Screen

2.
To keep the current retry count setting, press ENTER. To change the retry count setting,
enter the new value and then press ENTER. Entry can be any value from 0 to 255.
The user will be returned to the Second Configuration Menu.
3.
Prior to exiting the First Configuration Menu, select "Save changes then restart" to save
changes and restart the WAG.
Document No.: COM-00-05-16
Version: C.1
INSTALLATION AND CONFIGURATION
2-39
June 2006, Revised June 2014