INSTALLATION AND CONFIGURATION
2.6.31

WAG Site ID

The WAG Site ID is a unique ASCII string used to identify the WAG location.
To change the WAG Site ID:
1.
On the Third Configuration Menu, select "Change WAG Site ID" to be changed. The Change
WAG Site Name screen appears.
2.
On the screen in figure 2-64, do one of the following:
a. To retain the current WAG Site Name, press ENTER.
b. To change the WAG Site Name, enter an ASCII string of up to 40 characters. Entries can
consist of A-Z, 1-9 and 0, and ASCII symbols. After entering the site name, press ENTER.
The user will be returned to Third Configuration Menu.
3.
Prior to exiting the First Configuration Menu, select "Save changes then restart" to save
changes and restart the WAG.
4.
Following the save, the WAG Site ID can be viewed using the SCON command to show the
current configuration.
2.6.32

Route RAW Echelon: No

In previous executive software releases for the WAG, RAW Echelon frames (such as those received
from an iLOD) were sent to all other WAGs, which then transmitted the Echelon frame out their
Echelon interfaces.
The WAG executive software releases, A01E and later, support this as a configuration setting
option. When it's configured to NO, any RAW Echelon messages that come into the WAG from its
Echelon interface are ignored.
The WAG defaults this configuration setting to: NO.
Document No.: COM-00-05-16
Version: C.1

Figure 2-64. Change WAG Site Name Screen