Tcp Port Assignments; Figure 2-21. Broadcast Interface Screen - Siemens A53457 Installation & Maintenance

Wayside access gateway wag
Table of Contents

Advertisement

INSTALLATION AND CONFIGURATION
2. Select the desired broadcast medium and press ENTER.
3. To exit without making a change, select "Exit without making a change"..
When finished, the user will be returned to the First Configuration Menu.
4. Prior to exiting the First Configuration Menu, select "Save changes then restart" to save
changes and restart the WAG.
2.6.10

TCP Port Assignments

TCP port assignments are available when connection based messaging is to be used by the WAGs
to communicate across the Ethernet. Both WAGs must have the same port number configured for
serial Telnet.
TCP port numbers 9999 and 10000 are protected. The user cannot specify these port numbers.
To Assign TCP Port Numbers:
1. On the First Configuration Menu, select "TCP ports" assignments to be changed. The TCP
configuration screen appears. The TCP port assignment defaults are; 23, 6001, 6001, and 6002.
Socket number 23 is the Internet standard number (or "well known socket
number") for Telnet. Well known socket number 10023 provides a Telnet session
that directly accesses the WAG serial interface. Any of the four TCP slots may
be configured to either well known socket numbers for this mode of operation.
Document No.: COM-00-05-16
Version: C.1

Figure 2-21. Broadcast Interface Screen

2-20
NOTE
June 2006, Revised June 2014