2.6.5

WAG Test Mode

This function is for future application and is not operational at this time. Leave it Disabled.
2.6.6

Echelon Address

Changing the Echelon address lets the user specify the Echelon address the WAG has on the
twisted pair Echelon network. The user should ensure that a unique Echelon address is used for
each piece of equipment on the network.
Prior to starting, ensure the user has available the complete Echelon address to be used.
If the WAG is being used with the 53201 HD/LINK Vital I/O, leave the default
settings of subnet 01 and node 01.
To Assign an Echelon Address:
1. On First Configuration Menu, select "Echelon address" to be changed. The Change Echelon
Address configuration screen appears prompting for the subnet address (first two digits of
Echelon address).
2. Do the following:
a. To keep the current subnet address value, press ENTER. To enter a new value, type the
two digits of the new Echelon subnet address and press ENTER.
Set the subnet field to 1 to use with Safetran equipment. It is recommended to
set the node address to the same value as the sub-node field of the Type 7
ATCS Address.
The Change Echelon Address configuration screen next prompts for the node address (second
two digits of Echelon address).
b. To keep the current node address value, press ENTER. To enter a new value, type the two
digits of the new Echelon node address and press ENTER.
When finished, the user will be returned to the First Configuration Menu. The new Echelon
address is listed.
Document No.: COM-00-05-16
Version: C.1

Figure 2-18. Echelon Configuration Screen

2-17
INSTALLATION AND CONFIGURATION
NOTE
NOTE
June 2006, Revised June 2014