7
MES INTERFACE FUNCTION CONFIGURATION TOOL
Tag component
7
- 98
7.11 Job Setting - Actions
7.11.2 Setting items in Communication action (Select/Update/Insert/MultiSelect/Delete)
(c) When [Insert] is selected for [Action type]
[Insert] generates a new record, and inserts an insert value (tag component value/
constant value/variable) into a field of the generated record.
1) Field name (Up to 32 characters)
Set a field name for the field value to be inserted.
For characters that can be used for field names, refer to the following:
Appendix 2.4 Characters available for field names, table names, stored
procedure names,etc.
For browsing the field names in the database, refer to the following:
(8) Browse field name in this section
2) Tag
Select a tag, constant, or variable which is substituted.
Note that tags with [Array setting] are not selectable.
3) Component
Select or directly enter a component/constant value/valuable that is to be
substituted.
Database: DB1, Table name: ERRORLOG
Date
:
2005.07.01 15:12:00
Inserted
Constant: Module time
2005.07.01 15:12:00
Figure 7.75 Operation example of [Insert]
Figure 7.74 Setting example of [Insert]
Work_No
Process_No
:
1
536
Inserted
Constant: 1
Process1.Work_No
1
536
Parameter
:
:
8
Inserted
Inserted
Process1.Parameter