Operations
SNMP <Configure>
Sets SNMP. Three targets can be set as SNMP trap destinations.
≥ Change the settings, then select "Submit" to accept the change.
Enabled
Port (UDP)
Target 1 - IP Address
Target 2 - IP Address
Target 3 - IP Address
Community Name
MIB File
Power Supply Monitoring<Configure>
It is possible to monitor the power supply. (Only when an external power supply that supports power supply
monitoring functionality is used)
≥ Change the settings, then select "Submit" to accept the change.
Enable Power Supply
Monitoring
Web interface operation
Selects the use or non-use of SNMP.
≥ This function is disabled in the initial setting.
≥ It is necessary to configure "Port (UDP)" if this function is enabled.
Sets a port.
≥ This item becomes available after "Enabled" is check marked (SNMP is
enabled).
≥ SNMP normally uses Port 161, but if is in use by another application, set the
desired port.
Sets the IP address and the SNMP Version of Target 1/2/3.
Sets an SNMP community name.
≥ The initial setting is "da-public".
To improve security, it is recommended that the initial setting be changed
according to a setting made on the SNMP manager.
≥ A maximum of 256 characters can be input.
Download MIB files.
Enables/disables power supply monitoring.