List of error codes

Email
Code
notification
E1000
±
E1010
±
E1030
±
E1040
E1060
±
E1070
±
E1080
±
E1090
±
E2000
E2001
E2002
E2003
E2004
E2010
±
E2011
E2012
E2013
E2014
E2015
E2016
Errors and warnings
SNMP trap
notification
A fault has been detected in flash memory in the unit or the
±
peripheral circuit.
It needs to be repaired.
The internal temperature of the unit is high.
)Check if the exhaust port of the fan of the unit is being clogged
with an obstacle, and if yes, remove the obstacle.
)Check the log records to determine if the fan has a fault, and if
yes, it needs to be repaired.
±
If the problem persists, please contact your support service
provider. (
)The fan works when the unit starts up or the unit requires cooling
during operation.
An error has been detected during the software processing in the unit.
)Turn off and on the unit, and try again.
±
If it still does not operate, it needs to be repaired.
Failed to turn on the Extension Module.
±
It needs to be repaired.
The number of modules could not be found properly due to a
malfunction of the circuit board in the Extension Module.
±
It needs to be repaired.
A self-diagnostic test has detected a malfunction in the fan inside
the unit.
±
It needs to be repaired.
The number of USB hubs connected between the unit and server
exceeds the maximum limit.
±
)Reduce the number of USB hubs that are connected between the
devices. For example, change the USB port on the server or connect
the devices directly without placing USB hubs between them.
Self-diagnosis has detected an error in the changer mechanism in
the changer unit or the peripheral circuit of the changer mechanism.
It needs to be repaired.
±