HUAWEI MU509 Series HSDPA LGA Module
Hardware Guide
The level status of WAKEUP_IN signal is high by default.

3.4.5 WAKEUP_OUT Signal

The WAKEUP_OUT signal is used to wake up the external system.
WAKEUP_OUT signal is low by default. When a phone call or an SMS is coming, the
MU509 module will output a high pulse which lasts for 1s.
Within the duration of the high pulse, if a new phone call or an SMS is coming, the
MU509 module will output the high pulse over again.
Figure 3-14 WAKEUP_OUT sequence
Figure 3-15 Connections of the WAKEUP_IN and WAKEUP_OUT pins
Issue 09 (2014-03-06)
VCC_EXT2
WAKEUP_IN
Module
(DCE)
WAKEUP_OUT
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Description of the Application Interfaces
2.2 kΩ
2.2 kΩ
c
b
1 nF
e
2.2 kΩ
c
b
e
Micro Control
(DTE)
2.2 kΩ
VCC_EXT