Line supply voltage
400 V / 500 V / 690 V
With dv/dt filter plus VPL (option L10)
380 V – 480 V 3AC
500 V – 600 V 3AC
660 V – 690 V 3AC
With sine-wave filter (option L15)
380 V – 480 V 3AC
500 V – 600 V 3AC
Permissible motor cable lengths for SINAMICS G150 (continued)
Under certain conditions, the permissible cable lengths can be increased even further through the series connection
of two motor reactors. A second motor reactor is not a standard option and may require an additional cabinet.
Information about permissible cable lengths, the limitations associated with them and clarification as to whether an
additional cabinet will be required for two motor reactors is available on request.

SINAMICS G150 parallel converters (SINAMICS G150 power extension)

SINAMICS G150 converter cabinet units in the higher-output range are designed as parallel-connected converters.
The devices are based on two lower-output SINAMICS G150 converter cabinets which operate in parallel to supply
one motor.
Supply connection
Motor connection
(-X1)
Main switch (-Q1)
SINAMICS G150 parallel converter
Output power at
e.g. Protodur NYCWY
110 kW - 560 kW
110 kW - 560 kW
75 kW - 800 kW
110 kW - 250 kW
110 kW - 132 kW
Customer terminal block
(-A60)
Supply connection
(-X2)
(-X1)
Maximum permissible motor cable length
Shielded cable
300 m
300 m
300 m
300 m
300 m
Motor connection
(-X2)
Main switch (-Q1)
SINAMICS Engineering Manual - May 2008
SINAMICS G150
Engineering Information
Unshielded cable
e.g. Protodur NYY
450 m
450 m
450 m
450 m
450 m
Operator panel