Siemens SINAMICS G130 Engineering Manual page 248

Hide thumbs Also See for SINAMICS G130:
Table of Contents

Advertisement

SINAMICS S120 Cabinet Modules
Engineering Information
Basic Line Modules
The auxiliary voltage for Basic Line Modules is connected by means of cables supplied with the module. The
connection should be made to the auxiliary voltage busbar of the adjacent Motor Module where possible. The
following components require auxiliary power:
24 V DC:
Control electronics
Fuse protection down-circuit of the auxiliary voltage busbar is provided in the Cabinet Module.
The power unit fans are supplied directly via the line-side input terminals for Basic Line Modules. A separate
connection is not needed.
Order No.
Frame
size
Supply voltage 380 V – 480 V 3AC (DC link voltage 510 V – 650 V)
6SL3730-1TE34-2AA0
FB
6SL3730-1TE35-3AA0
FB
6SL3730-1TE38-2AA0
FB
6SL3730-1TE41-2AA0
GB
6SL3730-1TE41-2BA0
GB
6SL3730-1TE41-2BC0
GB
6SL3730-1TE41-5AA0
GB
6SL3730-1TE41-5BA0
GB
6SL3730-1TE41-5BC0
GB
6SL3730-1TE41-8AA0
GD
6SL3730-1TE41-8BA0
GD
6SL3730-1TE41-8BC0
GD
Supply voltage 500 V – 690 V 3AC (DC link voltage 675 V – 930 V)
6SL3730-1TH33-0AA0
FB
6SL3730-1TH34-3AA0
FB
6SL3730-1TH36-8AA0
FB
6SL3730-1TH41-1AA0
GB
6SL3730-1TH41-1BA0
GB
6SL3730-1TH41-1BC0
GB
6SL3730-1TH41-4AA0
GB
6SL3730-1TH41-4BA0
GB
6SL3730-1TH41-4BC0
GB
6SL3730-1TH41-8AA0
GD
6SL3730-1TH41-8BA0
GD
6SL3730-1TH41-8BC0
GD
1)
Power requirement of control electronics
SINAMICS Engineering Manual – May 2008
248/396
© Siemens AG
Rated power
Rated Input current
at 400 V resp. 690 V
[kW]
200
250
400
560
560
560
710
710
710
900
900
900
250
355
560
900
900
900
1100
1100
1100
1500
1500
1500
Current requirement
I
24 V DC
rated
[A]
[A]
365
1.1
460
1.1
710
1.1
1010
1.1
1010
1.1
1010
1.1
1265
1.1
1265
1.1
1265
1.1
1630
1.1
1630
1.1
1630
1.1
260
1.1
375
1.1
575
1.1
925
1.1
925
1.1
925
1.1
1180
1.1
1180
1.1
1180
1.1
1580
1.1
1580
1.1
1580
1.1
1)
400 V resp. 690V AC
50 Hz
60 Hz
[A]
[A]
0.5
0.6
0.5
0.6
0.5
0.6
1.8
2.6
1.8
2.6
1.8
2.6
1.8
2.6
1.8
2.6
1.8
2.6
1.8
2.6
1.8
2.6
1.8
2.6
0.3
0.4
0.3
0.4
0.3
0.4
1.1
1.6
1.1
1.6
1.1
1.6
1.1
1.6
1.1
1.6
1.1
1.6
1.1
1.6
1.1
1.6
1.1
1.6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g150Sinamics s120Sinamics s120 chassisSinamics s150

Table of Contents