9.4 Spare parts

Figure 9-2
Procedure
● Before you form the DC link capacitors, the DC link bridge must be removed.
● It is not permissible that the drive unit receives a power-on command (e.g. from the
● Connect the forming circuit.
● During the forming process, the incandescent lamps must become less bright or go
9.4
Spare parts
For a list of spare parts, see:
http://support.automation.siemens.com/WW/view/de/16612315
486
Motor Module interface
keyboard, BOP20 or terminal strip).
completely dark. If the incandescent lamps continue to be brightly lit, a fault has occurred
in the drive unit or in the wiring.
Equipment Manual, (GH2), 07/2007, 6SL3097-2AC00-0BP5