4.3.3.4

X21/X22 EP terminals / temperature sensor connection Motor Module

Table 4-15
Terminal block X21/X22
Terminal
1
2
3
4
Max. connectable cross-section 1.5 mm
Type: Screw terminal 1 (see Connection systems)
NOTICE
The KTY temperature sensor must be connected with the correct polarity.
Note
The temperature sensor connection is required for motors for which the temperature value is
not transferred using DRIVE-CLiQ.
If the "Safe standstill" function is selected, for operation, ground must be placed at the
-X21:3 24 V DC and the -X21:4 terminal. Upon removal, pulse suppression is activated.
4.3.3.5

X200-X203 DRIVE-CLiQ interface

Table 4-16
DRIVE-CLiQ interface X200-X202: Single Motor Module
DRIVE-CLiQ interface X200-X203: Double Motor Module
Pin
1
2
3
4
5
6
7
8
A
B
Blanking plate for DRIVE-CLiQ interface: Yamaichi, order no.: Y-ConAS-13
Booksize Power Units
Equipment Manual, (GH2), 07/2007, 6SL3097-2AC00-0BP5
Function
+ Temp
- Temp
EP +24 V (enable pulses)
EP M1 (enable pulses)
2
Name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+ (24 V)
GND (0 V)
4.3 Motor Module with external air cooling
Technical data
Temperature sensor connection KTY84–1C130/PTC
Supply voltage: 24 V DC (20.4 V - 28.8 V)
Current consumption: 10 mA
Optically isolated input
Signal propagation times:
L → H: 100 μs
H → L: 1000 μs
Technical specifications
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply
Electronics ground
Motor Modules Booksize
307