X21/X22 Ep Terminals/Temperature Sensor Motor Module - Siemens SINAMICS S120 Equipment Manual

Booksize power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

4.2.3.4

X21/X22 EP terminals/temperature sensor Motor Module

Table 4-3
Terminal block X21/X22
Terminal
1
2
3
4
Max. connectable cross-section 1.5 mm
Type: Screw terminal 1 (see Connection System)
NOTICE
The KTY temperature sensor must be connected with the correct polarity.
Note
The temperature sensor is required for motors for which the temperature value is not
transferred using DRIVE-CLiQ.
If the "Safe torque Off" function is selected, for operation, ground must be placed at the
-X21:3 24 V DC and the -X21:4 terminal. Upon removal, pulse suppression is activated.
Booksize power units
Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
Function
+ Temp
- Temp
EP +24 V (enable pulses)
EP M1 (enable pulses)
2
4.2 Motor Modules with internal air cooling
Technical specifications
Temperature sensor KTY84–1C130/PTC
Supply voltage: 24 V DC (20.4 V - 28.8 V)
Current consumption: 10 mA
Isolated input
Signal propagation times:
L → H: 100 μs
H → L: 1000 μs
Motor Modules Booksize