Mounting; Technical Data - Siemens SINAMICS S120 Equipment Manual

Booksize power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

6.4.5

Mounting

See the instructions for installing other DC link components (e.g. Braking Module, Capacitor
Module).
Arrangement of the Voltage Clamping Module
The Voltage Clamping Module should ideally be placed directly next to the Line Module.
● For Line Modules up to and including 36 kW, it should be placed to the right of the Line
● For Active Line Modules as of 55 kW, it should be placed to the left of the Line Module
● If the Voltage Clamping Module is to be installed in an existing drive line-up, it can also
6.4.6

Technical data

Table 6-10
Technical data
Voltage Clamping Module
Electronics power supply
DC link voltage
DC link busbar current carrying
capacity
24 V busbar
current carrying capacity
Power loss
1)
Weight
1) For an overview, see the power loss tables in Chapter Cabinet design
Booksize power units
Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
Module.
due to the current-carrying capacity of the DC link busbars.
be placed at the end.
V
DC
V
DC
A
A
W
kg
Booksize DC Link Components
6.4 Voltage Clamping Module
24 (20.4 - 28.8)
510 - 720
100
20
50
3.1
433