Siemens SINAMICS S120 Equipment Manual page 176

Booksize power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Line Modules Booksize
3.3 Active Line Modules with external air cooling
CAUTION
The total length of all the power cables (motor supply cables and DC link cables) must not
exceed 350 m in active mode.
CAUTION
Only cables from Siemens must be used for DRIVE-CLiQ connections.
NOTICE
The external air cooling can cause the fans and the heat sink to become heavily
contaminated, which may trigger the temperature monitor in the power unit. The fans and
heat sink must be checked for contamination at regular intervals and, if necessary, cleaned.
Note
After installation, the seal on the rear of the device must be checked to ensure that it is tight.
Additional sealing can be used, if necessary.
CAUTION
The DC link side covers are supplied as standard with the components; they can also be
ordered separately, if required (order no.: 6SL3162-5AA00-0AA0).
If the Line Module is not disconnected from the network (e.g. via the main contactor or main
circuit-breaker), the DC link remains charged.
176
WARNING
Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
Booksize power units

Advertisement

Table of Contents
loading

Table of Contents