Siemens SINAMICS S120 Equipment Manual page 308

Booksize power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Line Modules Booksize
3.8 Smart Line Modules (5 kW und 10 kW) with external air cooling
Figure 3-94
Example 2: installation in cabinet with mounting plate
We recommend that you attach a cover and filtered fan to the cabinet.
The filtered fan must be fitted in such a way that the cooling air required by the drive line-up
is not restricted. This can be determined by establishing the total cooling air required by the
individual components. This information is available in the technical data.
Note
If the cooling air requirement is not covered by the filtered fan, the components cannot
output their specified power.
The filters with a filtered fan must be regularly checked for dirt and cleaned if necessary.
308
Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
Booksize power units

Advertisement

Table of Contents
loading

Table of Contents