Motor Modules Booksize
4.2 Motor Modules with internal air cooling
4.2.3.4

X21/X22 EP terminals / temperature sensor connection Motor Module

Table 4-3
Terminal block X21/X22
Terminal
1
2
3
4
Max. connectable cross-section 1.5 mm
Type: Screw terminal 1 (see Connection systems)
NOTICE
The KTY temperature sensor must be connected with the correct polarity.
Note
The temperature sensor connection is required for motors for which the temperature value is
not transferred using DRIVE-CLiQ.
If the "Safe standstill" function is selected, for operation, ground must be placed at the
-X21:3 24 V DC and the -X21:4 terminal. Upon removal, pulse suppression is activated.
282
Function
+ Temp
- Temp
EP +24 V (enable pulses)
EP M1 (enable pulses)
2
Technical data
Temperature sensor connection KTY84–1C130/PTC
Supply voltage: 24 V DC (20.4 V - 28.8 V)
Current consumption: 10 mA
Optically isolated input
Signal propagation times:
L → H: 100 μs
H → L: 1000 μs
Equipment Manual, (GH2), 07/2007, 6SL3097-2AC00-0BP5