Line Modules Booksize
3.6 Smart Line Modules (16 kW und 36 kW) with internal air cooling
3.6.3.4
X200-X202 DRIVE-CLiQ interfaces
Table 3-45
DRIVE-CLiQ interface X200-X202
PIN
1
2
3
4
5
6
7
8
A
B
Blanking plate for DRIVE-CLiQ interface: Yamaichi, order no.: Y-ConAS-13
240
Signal name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+ (24 V)
M (0 V)
Technical specifications
Transmit data +
Transmit data -
Receive data +
Receive data -
24 V power supply
Electronics ground
Equipment Manual, (GH2), 07/2007, 6SL3097-2AC00-0BP5