4 Firmware Drive Functions
4.3 Closed-loop velocity control
5201
OUTPUT_VCTRL_FILTER_CONFIG [n]
Control output filter type in velocity controller
Unit:
Default:
-
0
5202
OUTPUT_VCTRL_FIL_1_FREQ [n]
Natural frequency output filter 1 velocity controller
Unit:
Default:
Hz
1000.0
5204
OUTPUT_VCTRL_FIL_2_FREQ [n]
Natural frequency output filter 2 velocity controller
Unit:
Default:
Hz
1000.0
4-112
0...7 index of the parameter set
Minimum:
Maximum:
0
3
Table 4-2
Control output filter type in velocity controller
1st filter
1st filter
Bit 0
Bit 0
2nd filter
2nd filter
Bit 1
Bit 1
Table 4-3
Filter combinations
Filter 2
Filter 1
PT2
PT2
BS
BS
0...7 index of the parameter set
Minimum:
Maximum:
10.0
8000.0
0...7 index of the parameter set
Minimum:
Maximum:
10.0
8000.0
The filter key data is defined in MD 5202 to MD 5205 and MD 5210 to MD 5215.
Enter the natural frequency for control output filters 1...2 (PT2 low-pass) in the
velocity controller.
The filters are activated in MD 5200: NUM_OUTPUT_VCTRL_FILTERS and
MD 5201: OUTPUT_VCTRL_FILTER_CONFIG.
SINUMERIK 840D/SIMODRIVE 611 digital, HLA Module (FBHLA) - 10.03 Edition
Related to:
HLA
Data type:
UNS.WORD
0
Low-pass (see MD 5202/5203)
1
Bandstop filter (refer to MD
5210/5211/5212)
0
Low-pass (see MD 5204/5205)
1
Bandstop filter (refer to MD
5213/5214/5215)
MD 5201: OUTPUT_VCTRL_FILTER_CONFIG
PT2
BS
PT2
BS
Related to:
HLA
Data type:
FLOAT
Related to:
HLA
Data type:
FLOAT
 Siemens AG, 2003. All rights reserved
04.00
10.03
Cross reference: -
Protection level:
3/3
Active:
Immediately
0
1
2
3
Cross reference: -
Protection level:
3/3
Active:
Immediately
Cross reference: -
Protection level:
3/3
Active:
Immediately