Siemens Sinumerik 840D Series Function Manual page 126

Hla module
Hide thumbs Also See for Sinumerik 840D Series:
Table of Contents

Advertisement

4 Firmware Drive Functions
4.5 Manipulated voltage output
5482
DUAL_GAIN_COMP_SMOOTH_Z_R [n]
Knee-point compensation rounding in zero range
Unit:
Default:
%
0.0
5483
NEG_DUAL_GAIN_COMP_Z_FLOW [n]
Knee-point compensation neg. flow in zero range
Unit:
Default:
%
0.01
5484
NEG_DUAL_GAIN_COMP_Z_VOL T [n]
Knee-point compensation neg. voltage in zero range
Unit:
Default:
%
0.0
5464
POS_DUAL_GAIN_COMP_FLOW [n]
Knee-point compensation pos. flow
Unit:
Default:
%
10.0
5465
POS_DUAL_GAIN_COMP_VOL TAGE [n]
Knee-point compensation pos. voltage
Unit:
Default:
%
10.0
5466
DUAL_GAIN_COMP_SMOOTH_RANGE [n]
Rounding range for knee-point compensation
Unit:
Default:
%
2.5
4-126
0...7 index of the parameter set
Minimum:
Maximum:
0.0
10.0
0...7 index of the parameter set
Minimum:
Maximum:
0.01
95.0
0...7 index of the parameter set
Minimum:
Maximum:
0.0
95.0
To calculate the inverse characteristic, a knee-point is defined in the positive
zero range of the valve characteristic with MD 5480 and MD 5481 and in the
negative zero range with MD 5483 and MD 5484.
The positive and negative valve flows at the knee-point in relation to the
nominal flow (MD 5107) are entered in 5483 and MD 5480 respectively.
The valve voltage at the knee-point in relation to the nominal valve voltage
(MD 5109) is entered in MD 5481.
When MD 5481 is set to default zero, there is no breakpoint in the positive
zero range.
When MD 5484 is set to default zero, there is no breakpoint in the negative
zero range.
The rounding range is parameterized in MD 5482.
S
Valve characteristic with breakpoint in fine control range
0...7 index of the parameter set
Minimum:
Maximum:
0.2
95.0
Minimum:
Maximum:
0.2
95.0
Minimum:
Maximum:
0.0
10.0
SINUMERIK 840D/SIMODRIVE 611 digital, HLA Module (FBHLA) - 10.03 Edition
Related to:
HLA
Data type:
FLOAT
Related to:
HLA
Data type:
FLOAT
Related to:
HLA
Data type:
FLOAT
Related to:
HLA
Data type:
FLOAT
0...7 index of the parameter set
Related to:
HLA
Data type:
FLOAT
0...7 index of the parameter set
Related to:
HLA
Data type:
FLOAT
 Siemens AG, 2003. All rights reserved
10.03
Cross reference: -
Protection level:
3/3
Active:
Immediately
Cross reference: -
Protection level:
3/3
Active:
Immediately
Cross reference: -
Protection level:
3/3
Active:
Immediately
Cross reference: -
Protection level:
3/3
Active:
Immediately
Cross reference: -
Protection level:
3/3
Active:
Immediately
Cross reference: -
Protection level:
3/3
Active:
Immediately

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 digitalSinumerik 840dieSinumerik 840dSinumerik 840deSinumerik 840di

Table of Contents