4 Firmware Drive Functions

4.5 Manipulated voltage output

4.5
Manipulated voltage output
4.5.1
Characteristic compensation
Area adaptation
5462
AREA_FACTOR_POS_OUTPUT [n]
Piston surface adaptation factor, positive
Unit:
Default:
%
100.0
5463
AREA_FACTOR_NEG_OUTPUT [n]
Piston surface adaptation factor, negative
Unit:
Default:
%
100.0
4-124
Various non-linear effects of valve or drive can be compensated by means of
characteristics. The characteristics are cascaded so that they can be set sepa-
rately.
0...7 index of the parameter set
Minimum:
Maximum:
50.0
200.0
0...7 index of the parameter set
Minimum:
Maximum:
50.0
200.0
In order to compensate the direction-dependent controlled-system gain on dif-
ferential cylinders, a characteristic with a gradient that is variable as a function
of direction has been implemented. Fig. 4-14 shows a sample characteristic and
illustrates how the associated machine data works. In practice, only one of the
two gradients is weighted with a factor not equal to 100%. Normally, it is the
gradient that causes the cylinder piston to travel out that is weighted with a fac-
tor of less than 100% (see also Subsection 2.3.1 and Appendix A).
Fig. 4-14
Example of piston surface adaptation characteristic
SINUMERIK 840D/SIMODRIVE 611 digital, HLA Module (FBHLA) - 10.03 Edition
Related to:
HLA
Data type:
FLOAT
Related to:
HLA
Data type:
FLOAT
Output
100%
MD 5462
-100%
0
-100%
- MD 5463
-200%
 Siemens AG, 2003. All rights reserved
10.03
Cross reference: -
Protection level:
3/3
Active:
Immediately
Cross reference: -
Protection level:
3/3
Active:
Immediately
Input
100%

Hide quick links: