Diagnostic machine data

5700
TERMINAL_STATE
Status of binary inputs
Bit 0: 26.5 V supply available
Bit 1: Term. 663 available
Bit 2: Term. 63 available
Bit 3: HW enable aggregate signal set
Bit 5: Setup mode selected
Bit 6: Term. 64 available
Bit 12: 24 V servo solenoid valve ON
Bit 13: 24 V shutoff valve ON
Unit:
Default:
HEX
0
5704
ACTUAL_PRESSURE_A
Actual pressure A
Unit:
Default:
bar
0.0
5705
ACTUAL_PRESSURE_B
Actual pressure B
Unit:
Default:
bar
0.0
5706
DESIRED_SPEED
Velocity setpoint
Unit:
Default:
mm/min
0.0
5707
ACTUAL_SPEED
Actual velocity value
Unit:
Default:
mm/min
0.0
5709
VOLTAGE_LSB
Significance of voltage representation
Defines how many volts [V] correspond to 1 increment
of the internal voltage format (valve spool setpoint/actual
value).
Unit:
Default:
V
0.0
5710
PRESSURE_LSB
Significance of pressure representation
Defines the pressure in [bar] corresponding to 1
increment of the internal pressure format.
Unit:
Default:
bar
0.0
 Siemens AG, 2003. All rights reserved
SINUMERIK 840D/SIMODRIVE 611 digital, HLA Module (FBHLA) - 10.03 Edition
Various machine data is provided in the HLA module for diagnostic purposes.
NC diagnostic displays are available in a similar way to those used on electrical
drives.
Minimum:
Maximum:
0
FFFF
Minimum:
Maximum:
-10000.0
10000.0
Minimum:
Maximum:
-10000.0
10000.0
Minimum:
Maximum:
-240000.0
240000.0
Minimum:
Maximum:
-240000.0
240000.0
Minimum:
Maximum:
-100000.0
100000.0
Minimum:
Maximum:
-240000.0
240000.0
4 Firmware Drive Functions
4.14 Service functions
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
UNS.WORD
Immediately
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
FLOAT
Immediately
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
FLOAT
Immediately
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
FLOAT
Immediately
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
FLOAT
Immediately
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
FLOAT
Immediately
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
FLOAT
Immediately
4-161