Siemens Sinumerik 840D Series Function Manual page 203

Hla module
Hide thumbs Also See for Sinumerik 840D Series:
Table of Contents

Advertisement

02.99
10.03
Response
Remedy
Continue program
310 704
Explanation
Response
Remedy
Continue program
310 705
Explanation
Response
Remedy
Continue program
 Siemens AG, 2003. All rights reserved
SINUMERIK 840D/SIMODRIVE 611 digital, HLA Module (FBHLA) - 10.03 Edition
NC not ready.
Channel not ready.
NC stopped in response to alarm.
NC start disable.
The NC switches to follow-up mode.
Alarm display.
Interface signals are set.
See drive functions "FB / DB1" MD1002
Switch control system OFF and ON again.
Axis %1, drive %2 velocity controller clock cycle axially unequal
%1 = NC axis number
%2 = drive number
The speed controller cycle MD 5001: SPEEDCTRL_CYCLE_TIME must be
identical for both axes.
NC not ready.
Channel not ready.
NC stopped in response to alarm.
NC start disable.
The NC switches to follow-up mode.
Alarm display.
Interface signals are set.
Set velocity controller clock cycle in MD 5001: SPEEDCTRL_CYCLE_TIME to
an identical value for both axes.
Switch control system OFF and ON again.
Axis %1, drive %2 monitoring cycle axially unequal
%1 = NC axis number
%2 = drive number
On 2-axis modules, the monitoring cycle set in MD 5002:
MONITOR_CYCLE_TIME (monitoring cycle) must be identical for both axes.
NC not ready.
Channel not ready.
NC stopped in response to alarm.
NC start disable.
The NC switches to follow-up mode.
Alarm display.
Interface signals are set.
MD 5002: MONITOR_CYCLE_TIME (monitoring cycle) to an identical value for
both axes.
Switch control system OFF and ON again.
6 Hydraulics Diagnostics
6-203

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 digitalSinumerik 840dieSinumerik 840dSinumerik 840deSinumerik 840di