4 Firmware Drive Functions

4.13 Monitoring functions

4.13
Monitoring functions
4.13.1
Alarms
Power On alarms
5600
ALARM_MASK_POWER_ON
Concealable alarms (Power On)
Bit 4: "Measuring circuit measuring system"
Bit 5: Measuring circuit absolute track (incl. SSI encoder)
Bit 8: "Zero marker error"
Unit:
Default:
HEX
0
5612
ALARM_REACTION_POWER_ON
Config. shutdown response to PO alarms
Bit 0= 0: No enable signal cancellation in response to
internal errors
1: Enable signal cancellation in response to internal
errors
Unit:
Default:
HEX
0
5731
CL1_PO_IMAGE
Image ZK1_PO register
Unit:
Default:
HEX
0
RESET alarms
5601
ALARM_MASK_RESET
Concealable alarms (Reset)
Bit 7:
"Valve controller not responding"
Bit 8:
"Velocity controller at limit"
Bit 9:
"Encoder limit frequency exceeded"
Bit 10: "Piston position negative"
Bit 11: "Pressure sensing failed"
Bit 12: "Force limitation OFF"
Bit 13: "External valve voltage supply check Off"
("26.5 V monitoring""
Unit:
Default:
HEX
0
4-152
Minimum:
Maximum:
0
FFFF
Minimum:
Maximum:
0
FFFF
Minimum:
Maximum:
0
FFFF
With MD 5600: ALARM_MASK_POWER_ON can be set to conceal Power On
alarms. If the relevant bit is set to 0, the corresponding error monitoring function
is active. If the bit=1, the error monitoring function is suppressed. The default
setting is active for all monitoring functions.
With MD 5612: ALARM_REACTION_POWER_ON is set to configure change-
over of the relevant Power On alarm.
Alarm messages, see Chapter 6, numbers 300500...300599.
Minimum:
Maximum:
0
FFFF
SINUMERIK 840D/SIMODRIVE 611 digital, HLA Module (FBHLA) - 10.03 Edition
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
UNS.WORD
Immediately
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
UNS.WORD
Immediately
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
UNS.WORD
Immediately
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
UNS.WORD
Immediately