7 Peripherals/Accessories
7.2 BERO (X432)
7.2
BERO (X432)
7-226
Only BEROs of type 3-wire PNP NO contact may be used.
We recommend the following BERO models:
SIEMENS
BERO M30 3RG 4014-0AG01
BERO M12 3RG 4012-3AG01
Note
The BERO cable must be shielded.
Table 7-2
Pin assignment X432
Terminal name
B1/B2
19
9
1) I: Input, O: Output
SINUMERIK 840D/SIMODRIVE 611 digital, HLA Module (FBHLA) - 10.03 Edition
1)
Type
Signal designation
I
BERO (external reference system) axis 1/2
O
Power supply for BERO ground external
O
Power supply for BERO 24 V external
Siemens AG, 2003. All rights reserved
02.99
10.03