Siemens Sinumerik 840D Series Function Manual page 25

Hla module
Hide thumbs Also See for Sinumerik 840D Series:
Table of Contents

Advertisement

10.03
 Siemens AG, 2003. All rights reserved
SINUMERIK 840D/SIMODRIVE 611 digital, HLA Module (FBHLA) - 10.03 Edition
2.2 Integration in SINUMERIK 840D/SIMODRIVE 611 digital
Table 2-1
Components of SINUMERIK 840 digital control with HLA module (number,
component, description)
No.in
Component
Fig.
2-3
1)
L
Handheld unit
1)
M
Distribution box
N
Cable distributor
O
Hydraulic Drive
P
External 24 V supply
A description of these components can be found in:
1)
References:
/BH/, Operator Components Manual
Note
An HLA module must never be operated directly on a SIMODRIVE monitoring
module, i.e. it must always be connected via a mains infeed module.
For information about connecting further additional SIMODRIVE monitoring
modules in configurations with several HLA modules, please refer to the
Planning Guide for SIMODRIVE 611 Converters /PJU/.
In a multi-tier configuration, all the infeed supply units must be connected
simultaneously.
Description
S
Connect HHU to K bus via MPI
S
Handwheel, EMERGENCY STOP button, key-ac-
tuated switch, override, agreement buttons, dis-
play, unassigned keys
S
For linking the hand-held unit to the MPI bus
S
Connection for EMERGENCY STOP circuit, en-
able keys, handwheel, 24 V DC
S
24V supply for connection to MPI connector
References:
/BR1/,
"Servo solenoid valves" catalog
/BR2/, "Sensors and electronics" catalog
/BR3/, "Adapter plate valves" catalog
S
SITOP stabilized power supply modules
References: SITOP catalog
Order No. E860060-K2410-A101-A4
2 Configuration
2-25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 digitalSinumerik 840dieSinumerik 840dSinumerik 840deSinumerik 840di

Table of Contents