Detailed description
2.5 Linking PLC CPUs to 810D, 840D
All values must be converted to decimal values and lined up in order of alarm or message
number:
Event ID:
Supplementary
information 1
Supplementary
information 2
Alarm number (OM)
1) controlled by DB2.DBX184.0
OM = operational message
This signifies the event with Event ID 16# B046 and the indicated supplementary information
"Message 700032 deleted".
Notes
• The meaning of the message number is specified by the machine manufacturer.
• Events with Event ID 16# xx28 or 16# xx29 are generated from the basic program.
• The messages stored in the diagnostic buffer can be read out on the MMC with the
2-28
46
hex
00
hex
20
1)
associated message texts.
=
70
dec
=
00
dec
=
32
hex
dec
=
70 00 32
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
Power Line Basic PLC Program (P3)