7.1 Shielded terminal plates
Table 7-5
Electrical connection at the shielded terminal plate for 200 mm component using as an example, internal air
cooling
Unlock and remove the cover of the
terminal block.
Adjust the shock-hazard protection
using a suitable tool.
Close the cover of the terminal block.
7-16
Remove nuts M8 using a suitable tool.
Attach the shock-hazard protection.
Equipment Manual, (GH2), 03/2006 Edition, 6SL3097-2AC00-0BP3
Secure the earthing cable with
screwdriver T25 and the power cable
with torque spanner M8/13 Nm.
Secure the shield clip to the shielded
terminal plate using a suitable tool.
Equipment Manual for Booksize Power Units