DC link components Booksize
5.5 Voltage Clamping Module
5.5.5
Installation
See the instructions for installing other DC link components (e.g. Braking Module, Capacitor
Module).
Arrangement of the Voltage Clamping Module:
The Voltage Clamping Module should ideally be placed directly next to the Line Module.
• For Line Modules up to and including 36 kW, it should be placed to the right of the Line
• For Active Line Modules as of 55 kW, it should be placed to the left of the Line Module
• If the Voltage Clamping Module is to be installed in an existing drive line-up, it can also
5.5.6
Technical specifications
Table 5-10
Technical Specifications
Voltage Clamping Module
Electronics power supply
DC link voltage
DC link busbar current carrying
capacity
24 V busbar
current carrying capacity
Power loss
1
Weight
1 For an overview, see the power loss tables in Cabinet Design.
5-32
Module.
due to the current-carrying capacity of the DC link busbars.
be placed at the end.
V
DC
V
DC
A
A
W
kg
24 (20.4 - 28.8)
510 - 750
100
20
50
3.1
Equipment Manual for Booksize Power Units
Equipment Manual, (GH2), 03/2006 Edition, 6SL3097-2AC00-0BP3