Siemens SINAMICS S120 Equipment Manual page 277

Booksize power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Table 7-8
Installing the DC link supply adapter for 50 mm and 100 mm modules
Unlock and open the
protective cover.
Secure the adapter.
Equipment Manual for Booksize Power Units
Equipment Manual, (GH2), 03/2006 Edition, 6SL3097-2AC00-0BP3
Opened cover with 24 V
jumper and DC link bridge
Create the recess using
suitable pliers.
The DC link bridge and 24 V
jumper have been removed.
Plug-on the 24 V adapter
Options
7.2 DC link supply adapter
Removed DC link bridge and
screws
Close the protective cover.