Diagnostics
5.2 Diagnostics using LEDs
5.2.2.7
Braking Module in booksize format
Table 5- 10
Meaning of the LEDs on the Braking Module booksize
LED
Color
State
READY
–
Off
Green
Continuous
light
Red
Continuous
light
DC LINK
–
Off
Green
Flashing
light
5.2.3
Additional modules
5.2.3.1
Control Supply Module
Table 5- 11
Control Supply Module – description of the LEDs
LED
Color
State
READY
–
off
Green
Continuous
light
DC LINK
–
off
Orange
Continuous
light
Red
Continuous
light
146
Description, cause
Electronic power supply is missing or outside permissible
tolerance range.
Component deactivated via terminal.
Component is ready to operate.
Enable signal missing (input terminal)
Overtemperature
Overcurrent trip
I
t monitoring responded
2
Ground fault/short circuit
Note:
In the event of an overtemperature, the error cannot be
acknowledged until after a cooling down time.
There is no DC link voltage or the electronic power supply is
missing or outside permissible tolerance range.
Component not active.
Component active (DC link discharge via braking resistor in
progress).
Description, cause
Electronic power supply is missing or outside permissible
tolerance range.
Component is ready to operate.
Electronic power supply is missing or outside permissible
tolerance range.
DC link voltage within permissible tolerance range.
DC link voltage outside permissible tolerance range.
Commissioning Manual, (IH3), 07/2016, 6SL3097-4AA10-0BP0
Remedy
–
–
Diagnose fault (via
output terminals) and
acknowledge it (via
input terminal)
–
–
Remedy
–
–
–
–
–
Commissioning with Startdrive