The fibre connection must conform to both the Optical Budget and Fibre Length specifications. It is
possible to have a fibre connection longer than 3 km (1.86 miles) with less than 9 dB of loss; however,
the CTX670 Remote Expansion Cabinet is sensitive to signal delay and cannot be guaranteed to
operate at distances greater than 3 km (1.86 miles).
Status Indicators
The RRCU1A card set provides two status indicators: a set of LEDs on the ROMS1A card and an
RS232C Monitor Port on the RRCU1A. Status indications are provided according to
10. Binary Code Output is generated upon change of a reported condition.
Table 3-9
RS-232C Binary Code Output
BIT
Label
D0
SD
1: Optical signal not detected
0: Optical signal detected
D1
RDER
1: Code rule violation detected in received data
0: Code rule violation not detected in received data
D2
SYCF
1: Frame synchronisation of received data not established
0: Frame synchronisation of received data established
D3
SYCS
1: System synchronisation between cabinets not established
0: System synchronisation between cabinets established
D4
RST
1: Reset signal from CTU detected
0: Reset signal from CTU not detected
D5
Not Used
D6
Not Used
D7
Not Used
Table 3-10
LED Status Indications
LED
PWR
Blinking: Power is supplied
Off: Power is not supplied
SD
On: Optical signal not detected
Off: Optical signal detected
RDER
On: Code rule violation detected in received data
Off: Code rule violation not detected in received data
SYCF
On: Frame synchronisation of received data not established
Off: Frame synchronisation of received data established
SYCS
On: System synchronisation between cabinets not established
Off: System synchronisation between cabinets established
RST
On: Reset signal from CTU detected
Off: Reset signal from CTU not detected
Strata CTX I&M September 2002