Toshiba Strara CTX Series Installation And Maintenance Manual page 64

Digital business telephone systems
Table of Contents

Advertisement

Strata CTX100 Installation
4. Run the ABTC-3M battery cable from the batteries to the ABCS battery charger located in the
CTX100 power supply. Dress the battery cable within the CTX100 cabinet(s) carefully (see
Figures
2-10~2-13).
Important!
The CTX100 must be connected to the live operating (hot) AC power source, and the
power supply On/Off switch set to On prior to the final step of connecting the reserve
power battery cable to the ABCS battery charger. If the batteries are connected after AC
power is lost, reserve power will not function.
5. Connect the ABTC-3M battery cable two-prong female plug to the power supply
"CN-BAT" receptacle on the ABCS charger.
6. To test reserve power operation, disconnect the system AC power plug from the source outlet
while the power supply power On/Off switch in the On position. The AC and DC power lights
should be Off. The system should continue to operate without interruption or dropped calls.
7. Plug the AC power cable back into the outlet; make sure the power supply switch is On.
8. Confirm that the power supply is working properly. (AC Power lights should be On.)
Figure 2-10 Cable Wiring for the Base and Expansion Cabinets (Top view)
Base C abinet
Figure 2-11 Cable Wiring for a Base Cabinet Only (Side view)
2-12
C onnector of Battery C able to
Battery C harger C N-BAT C onnector
ABT C -3M Battery C able to Battery C harger
(T uck into plastic retainer with
AC power cord.)
5992
A BT C -3M Battery C able to the Battery C harger
A BT C -3M Battery C able is
sec ured with a tie wrap.
5993
Strata CTX I&M September 2002