6-32

6.2 8D Coaxial Cable

Procedure 6-7
Outlines of parts
Cable jacket
Center conductor
Braided wire
Tools
Cable jacket
In case of cable type A (φA)
1
Insertion of parts and remove of jacket of cable.
(1) The clamp nut, the washer are inserted in the cable.
(2) Remove 9 to 10 mm of jacket only.
Tools
Note
NWD-107460-02E
Submission Prohibited
NEC Internal Use Only
TNC-P Connector used for IDU IF IN/OUT
(L-angle: TNC141(R0))
[Applicable cable: 8D-FB-E]
Aluminum tape
Connector body
Insulator
knife, cutter, nipper, tweezers, file, measure,
clearance gauge, etc.
spanner, torque spanner 16 mm
Clamp nut
knife
cutter
measure, etc.
Do not damage the braided wire.
Spacer
Contact
cord tube
Diameter over cable jacket
φA or φB
φA: 11 mm
φB: 10 mm
Washer
9-10 mm
CABLE TERMINATION
Washer
Clamp nut
Clamp
Installation