WATERPROOF PROTECTION

After cable connection, the following parts should be wrapped by self-bonding tape
for waterproof (see Fig. 9-1).
Caution
Before connecting the IF cable between the IDU and ODU, using the circuit
tester, check that the resistance of the I/F cable between center conductor
and insulation is more than 100 MΩ
ANT
Note A
Note A
These parts should be wrapped
the self-bonding tape tightly, twice
or more around the IF cable
connector and IF IN/OUT
connector of the ODU for
waterproof.
Fig. 9-1 Location of Connector for Waterproof (1/2)
Installation
Submission Prohibited
NEC Internal Use Only
9. WATERPROOF PROTECTION
Pole
HYB/Coupler
ODU
ODU
6/7/8 GHz band ODU
.
ANT
Note A
Wrap twice the IF IN/OUT connector
with self-bonding tape for waterproofing.
Self-bonding
Stretch
ODU
A half of tape width
Twice
9-1
Pole
ODU
tape
NWD-107460-02E