Elevation Angle Adjustment (Waveguide Connection Type)

1
Make sure that all strut attachment hardware is loosened,
2
Loosen bolts indicated by arrows in Fig. 10-7,
3
Loosen jam nuts and rotate turnbuckle-2 in Fig. 10-7 so that the RX LEVEL
MON voltage obtains the maximum value,
4
Carefully, tighten turnbuckle-2 jam nuts and bolts indicated by arrows in Fig. 10-
7.
Torn bucle-2
Fig. 10-7 Location of Adjusting Nuts and Bolts (Elevation Adjustment)
NWD-107460-02E
Submission Prohibited
NEC Internal Use Only
B. Elevation Adjustment
ANDREW VHLP4 type bracket