ANTENNA ORIENTATION

After the initial setup has been completed, an antenna orientation will be performed
between two stations according to the following procedure .
Procedure
Apparatus
Digital Multimeter with test leads or X0818 PASOLINK Monitor Wrench
1
Connect the PC to the LCT port on the iPASOLINK IDU using LAN cable (see
Operation manual),
2
At each station, set Maintenance Control in LCT Menu,
Note
3
Click and select for the following control items in Maintenance Control,
Notes
• TX SW Manual Control:
• RX SW Manual Control:
• TX Power Control:
(at opposite site)
4
At receiving station, remove a cap from the RX LEV MON jack,
5
At each station connect the digital multimeter or PASOLINK Monitor to the RX
LEV MON jack on the ODU,
Installation
Submission Prohibited
NEC Internal Use Only
10. ANTENNA ORIENTATION
In Maintenance "On" condition, every external Alarm outputs, excluding
Maintenance/PS/CPU (IDU) ALM, are masked and remote control can
not be performed.
1.
Retain the present status for other control items.
2.
When the TX power control mode is set to ATPC, set it to MTPC and
required level for the PASOLINK link on the "Equipment Setup" and
"Provisioning".
Fix No.1 or No.2
(in 1+1 configuration)
Fix No.1 or No.2
(which is the same side fixed by TX SW in
1+1 configuration.)
MTPC in Equipment Setup
Required level in Provisioning
10-1
NWD-107460-02E