ODU MOUNTING
5.2.2

For Waveguide Connection

10-38 GHz ODU MOUNTING BRACKET INSTALLATION

This Mounting Bracket is designed in order to install 10-38 GHz ODU with antenna
direct mount interface to a pole. The diameter of the pole is from 48.5 to 114.3
millimeters.
Item
1
Bracket (with Adapter)
2
Holder-1 (with two M6 taps)
3
Holder-2
4
M8 Stud Bolt (SS)
5
M8 Hexagon Nut (SS)
6
M8 Flat Washer (SS)
7
M6×16 Hexagon Socket Head Screw (SS)
8
M6 Spring Lock Washer (SS)
9
M6 Flat Washer (SS)
10
Cap
11
O-Ring (for ODU)
12
O-Ring (for Waveguide)
13
Screw of Waveguide Connecting
for 10/11 GHz M4×14 Hexagon Head Screw with Washer (SS)
for 13/15 GHz M4×12 Hexagon Head Screw with Washer (SS)
for 18/23/26/28/32/38 GHz M3×10 Hexagon Head
Screw with Washer (SS)
SS: Stainless Steel
Note
Installation
Submission Prohibited
NEC Internal Use Only
Mounting Bracket
Table 5-7 Mounting Bracket Parts List
Description
Tightening torque is 4 N·m ±10% (M6 Screw).
Tightening torque is 11 N·m ±10% (M8 Screw)
5-49
Q'ty
1
2
2
4
20
8
4
4
4
4
1
1
8
4
4
NWD-107460-02E