DC link components
8.1 Braking Module
Layout
The Braking Module in the chassis format is inserted in a mounting location inside the Line
Module or Motor Module, whose fan force cools it. The supply voltage for the electronics is
drawn from the DC link. The Braking Module is connected to the DC link by means of the
busbar sets and flexible cables, which are supplied as standard.
The activation threshold of the Braking Module can be adjusted by means of a DIP switch.
The braking power values specified in the technical specifications apply to the upper
activation threshold.
The Braking Module has as standard, the following interfaces:
● The DC link is connected through busbars and flexible cables
● Connecting terminal for external braking resistor
● 1 digital input (inhibit Braking Module with high signal / acknowledge error with negative
edge high-low)
● 1 digital output (Braking Module inhibited)
● 1 DIP switch for adjusting the activation threshold
Note
Installing a Braking Module of frame size GX in a Basic Line Module of frame size GB or GD
To install a frame size GX Braking Module in a frame size GB or GD Basic Line Module a
cable harness set is required, which is available under Article number 6SL3366-2NG00-
0AA0.