Panasonic IMAGECHECKER PV230 Manual page 37

Functions excerpt edition
Table of Contents

Advertisement

Outputting Recognized Characters
For outputting recognized characters, select the setting from "General Output" ("ENVIRONMENT" ->
"Input/Output"). It can be selected for each character recognition checker whether or not recognized characters
will be output. For example, when 2 character recognition checkers (No.1 and No.2) have been created, it can
be selected to output the result of No.0 checker, but not to output the result of No.1 checker.
The characters to be output are "Judged Character".
1.
Select "Output Judged Characters".
2.
As for the character recognition checker
currently being set, to output recognized
characters, select "Yes". Select "No" not to
output.
Default: "Yes"
"General Output" setting
1.
Select "ENVIRONMENT" -> "Input/Output"
-> "General Output" from the menu bar.
2.
Select "Yes" for "Output" of the port
(Serial/Ethernet/SD/FTP) to which strings
are output.
3.
Select "General Com." or "PLC Com." in
"Protocol".
4.
Select "Yes" in "Optical Character
Recognition".
5.
Specify "No. of Output Characters".
Available numbers of characters are 1 to 80.
Specify the number of characters per
character recognition checker.
When the number of characters recognized with each character recognition
checker has exceeded "No. of Output Character", only the recognized characters
of the specified number from the beginning are output.
If the character string on the right is recognized, only 5 characters "HELLO" from
the beginning will be output when "No. of Output" is set to 5.
6.
Select "Unused Digit" from "Fill with 0" or "Comma Sep.".
If you select "Comma Sep.",
7.
Specify "Start"*,"Data Delimiter"*, "End"*.
*Available from PV230Ver.1.30.
*Available only for General Communication Protocol.
*These items are are valid if you setting "Unused Digit" to "Comma Sep."
procedure No.
valid.
7 will be