3.3.3 Training (2D Code Only)

What is Training?
Training is a function to read the status of the code captured and automatically set the code model
parameter.
By repeating trainings with multiple samples based on the specified "Current Value", it makes it easier for
flawed codes to be read.
Setting Example 1
(Reading Codes of Different Sizes)
To describe the setting method, it shows the
example using two codes.
Code 1 (DataMatrix)
No. of modules: 16x16 modules
Module size: Min. 9 pixels to Max. 10 pixels
Code 2 (DataMatrix)
No. of modules: 32x8 modules
Module size: Min. 6 pixels to Max. 7 pixels
About "Base Data on"
"Current val."
Additionally registers the result of training to the current
settings.
"Default Val."
Clears the current settings and registers the result of
training.
1.
Registering default values
3-1. Registering default values
Select "Default Val." in "Base Data on", adjust the view
range to capture the code 1 within the inspection area,
and execute "Training".
The settings of code 1 are registered in the
parameters.
Module Columns Min.: 16
Module Columns Max.: 16
Module Rows Min.: 16
Module Rows Max.: 16
72
Code 1
Code 2