4.1 General Output of Date and Time Information

PV has features of outputting judgements of inspections and results of numerical calculations through the I/O
terminal block, and the ports, and writing them in an attached SD memory card. Also, inspected images can be
output to a PC through Ethernet, or saved in a attached SD memory card.
With the former products, date and time information cannot be output when the output destination is Serial. With
Ver.1.20, however, the information can be output to external devices as general results. In this section, the setting
method of general output of date and time information is described.
For information on the settings for other output data such as judgement results or numerical calculation,
refer to the PV200 User's Manual "11.2.2 Setting General Communication".
Setting Inspection Environment
To output date and time information to external devices, make the operation setting in ENVIRONMENT menu first.
This setting is reflected in the setting window of "General Output" in Input/Output menu.
1.
Displays the setting window.
2.
Select "ENVIRONMENT" > "system Settings" >
"Operation" from the menu bar.
3.
Select "Date/Time of Genera Output".
"Yes": Date and time can be set in the setting window
of "General Output".
"No": Date and time cannot be set.
The default is "Yes".
• When reading the setting data of Ver.1.20 or earlier, "Date/Time" in "General Output" is set to "No".
For outputting date and time information using the setting data of old versions, make the above setting.。